  • AGA/Rayburn SERVICING

    • The guidelines for servicing intervals are as follows:-

      • Gas fired Aga/Rayburn (requires a service annually)
      • Oil fired Aga/Rayburn - pressure jet (requires a service annually)
      • Oil fired Aga/Rayburn - vaporising (requires a service every 6 months)


      During a routine service the following actions will normally be taken (these may vary dependent on model):-

      • Clean and inspect internal flue ways
      • Clean heat exchanger and baffles
      • Rope seals and gaskets will be inspected and replaced as necessary
      • Clean and inspect the burner(s)
      • Clean the carbon from the burner and oil feed (vapourising)
      • Clean the pilot injector (gas)
      • Replace thermocouple as standard (gas)
      • Replace wicks or nozzle and oil hose as standard (oil)
      • Check operation of ignition system and photocell
      • Check the operation of oil control box and clean the injector/stem
      • Clean the oil filters
      • Check the gas/oil pipework and condition of oil tank
      • Check flue safety thermostat or fire valve
      • Inspect the flue system and terminal
      • Clean and inspect fan units where applicable
      • Check for adequate ventilation
      • Clean out flue diverter and carry out spillage test
      • Relight burner(s)
      • Check gas/oil pressures or oil flow rates
      • Check the combustion and adjust as necessary
      • Check and adjust the operation of insulating lids and door 

         


       

    •  